RF Ammeter
Systems

Model
TCA-10/20-EXR RF Ammeter System
Introduction
The Transformer Coupled Ammeter (TCA)
series of RF Ammeters provides AM
broadcasters with an accurate and reliable instrument for measuring
common point and antenna base currents. The ammeter uses a toroidal
current transformer to obtain a sample voltage proportional to the RF
current flowing in a conductor. This voltage sample is connected by a
50 ohm coaxial cable to a temperature compensated rectifier circuit.
This circuit converts the RF voltage to a DC voltage which is applied
to a linear scale meter, calibrated in RF Amperes, for display of
current magnitude. The ammeter provides a DC output voltage to drive a
remote indication instrument which may be calibrated against the
primary meter and used for remote indication. The ammeter also includes
relays to enable remote control of the meter operation.
Description
The RF Ammeter system comprises a
toroidal
current transformer (TCT) unit, a rectifier/meter unit and an
interconnecting
coaxial cable. Depending on the RF conductor voltage, the transformer
unit may be either the
TCT-N
(10 kV
RMS
rating) transformer, the
TCT-N-HV
(20
kV
RMS
rating) transformer or the
TCT-N-XHV
(42.4 kV
RMS
rating) transformer. These transformer voltage ratings are the RMS
equivalent of the peak modulation voltage. Within each TCT type,
several versions are available depending on the RF current magnitude.
The TCT provides an RF voltage sample directly proportional to the
current. The voltage sample is applied to the rectifier/meter unit by a
50 ohm coaxial cable. The rectifier circuit provides a 50 ohm load
resistor for proper termination. This circuit converts the RF voltage
sample to a DC voltage for meter display. The rectifier filter circuit
is designed to follow the modulation envelope accurately. The meter
ballistics average
the audio content and thus, the meter indicates the RF carrier current.
The meter provides a stable reading independent of modulation, but may
deflect slightly under high modulation conditions due to carrier shift.
A switch on the unit provides local operation of the meter and selects
either the high or low scale for dual scale units. The rectifier/meter
unit also provides a DC output voltage plus the audio signal component
to drive a remote indicating instrument and relays for remote operation
of the meter. When the relays are not energized and the local switch is
in the off position, the rectifier circuit input is disconnected from
the RF input and grounded for lightning protection.
The RF Ammeter series
encompasses both single and dual scale
models
to provide RF current measurement over the range from 5 Amperes full
scale to 160 Amperes full scale. These current ranges follow the FCC
rules for linear scale meters. The minimum normal reading must be at
least 1/5 full scale, and the maximum reading must not exceed full
scale under normal power variations or modulation. Since the TCA series
meters do not respond to modulation, it is practical to use the meters
up to 95% of full scale.
The standard interconnecting
coaxial cable length is six feet.
Longer coaxial cable lengths and double shielded coaxial cable are
optionally
available for any TCA system for high RF field conditions and for RF
radiation exposure reduction.
Ammeter Accuracy and
Calibration
The RF Ammeter Systems are capable of
measuring RF current with
excellent accuracy. The accuracy specification of ±2% full scale
is guaranteed over a temperature range of -40° C (-40° F) to
+65° C (+150°F) and over a frequency range of 500 kHz to 2000
kHz. By using the
linearity correction chart on the calibration sheet included with the
ammeter, the meter accuracy may be improved to within ±1% full
scale.
Every RF Ammeter is calibrated
and sealed at the Delta
laboratory.
Each RF Ammeter is calibrated at a frequency of 1 MHz. The flat
frequency response and compensated temperature characteristics of the
ammeter assure accurate current measurement. The calibration of the RF
Ammeter is warranted for a period of one year under normal use
conditions. Excluding damage due to lightning, Delta will recheck the
calibration and make repairs, if necessary, without charge during this
period. These services are available at a nominal charge at any time
thereafter.
Meter Nomenclature
The TCA-EX and TCA-EXR series of RF
Ammeters include a wide variety of
scales, scale combinations, and
optional features, all of which are uniquely defined in the model
designation system.
TCA-N-EX:
The TCA-EX RF Ammeter
series has been
superseded by the TCA-EXR series. Information on the TCA-EX series is
included for legacy equipment applications. The TCA-EX model is a
single-scale meter with
external output. The system consists of a current transformer, a six
foot coaxial cable, and a meter enclosure housing the meter movement,
rectifier circuitry, and external output connector. The external output
can be used in conjunction with a series 10K Ohm variable resistor
connected to a second meter to provide for remote metering. The
external output may also be used to drive automatic logging, remote
control, or ATS equipment. A two-position toggle switch mounted on the
front of the meter box turns the circuit on and off, and when switched
off, protects the rectifier circuit against lightning damage. A
spring-loaded, momentary contact toggle switch is optionally available
to prevent leaving the ammeter in the on position.
TCA-N-EXR and
TCA-N/N-EXR: Meters
with the "-EXR"
suffix provide the external output for remote metering and an internal
relay for remote control of the ammeter. A two position toggle switch
provides local on/off operation. When the switch is in the off
position, the meter is remotely controlled by the operation of the
internal relay. When this relay is not energized and the local switch
is in the off position, the rectifier circuit input is disconnected
from the RF input and grounded for lightning protection. The
dual scale models include a second relay for changing scales remotely.
These relays are operated by a 24 VDC, 25 mA external power supply. The
dual-scale system allows selection of any two of the adjacent (N/2N)
scale ranges or selection of specific nonadjacent (N/4N) scale
ranges. For example, the TCA-20/40-EXR has a 4 to 20 ampere range on
its lower scale, and an 8 to 40 ampere range on its upper scale, and
the TCA-5/20-EXR has a 1 to 5 ampere range on its lower scale, and a 4
to 20 ampere range on its upper scale. A
three position toggle switch controls the metering function, where the
upper position is for the high scale, the lower position is for the
low scale, and the center position grounds the rectifier circuit and turns
the meter off.
The standard current transformer
supplied with the meter
is rated for operation
with conductor voltages as high as 14 kV peak (10 kV
RMS).
The transformer provides a 1.25" diameter insulated clearance hole for
the antenna conductor. A 0.38 to 0.5" diameter tubular conductor
centered in the clearance hole provides optimum
voltage capability. The
TCA-LS-8
and
TCA-LS-11
line sections which increase the voltage rating by approximately 50% are
available as a factory installed option.
TCA-N-EXR-HV:
The suffix "HV" appended to any of the
TCA series model numbers specifies that the current transformer
supplied with the meter is the high voltage type rated for operation at
conductor voltages as high as 28 kV peak (20 kVRMS).
The transformer provides a 3.38" diameter clearance hole for the
antenna conductor. A 0.75 to 1.0" diameter tubular conductor centered
in the clearance hole provides maximum voltage capability. Corona rings
which increase the voltage rating by approximately 5% are available as
a factory installed option.
TCA-N-EXR-XHV:
The suffix "XHV" appended to any of the
TCA series model numbers specifies that the current transformer
supplied with the meter is the extra high voltage type rated for
operation at conductor voltages as high as 60 kV peak (42.4 kVRMS).
The transformer provides a 6.0" diameter clearance hole for the antenna
conductor. A 2.0 to 2.25" diameter tubular conductor centered in the
clearance hole provides maximum voltage capability.
Installation Drawings and
External Connections Diagrams
For
case outline, mounting and
associated
installation dimensions, select from the following:
For remote meter, on/off or
low/off/high control
switch, and power supply connection
diagrams, select from the following:
Custom Meter Scales
The TCA RF Ammeters are available with custom meter scales to
provide special full scale current values such as 8 Amperes, 12 Amperes or 50
Amperes. Custom meter scales which provide a secondary scale calibrated in
Watts referenced to 50 Ohms are also available. Contact
Sales
to discuss your particular requirements.
125 kW at 50 Ohms and 50
Ampere Custom Meter Scale
Available Models
SINGLE SCALE MODELS |
Current Range (ARMS)
|
TCA-N-EXR
|
1-5
|
TCA-5-EXR |
2-10 |
TCA-10-EXR |
4-20 |
TCA-20-EXR |
8-40 |
TCA-40-EXR |
10-50 |
TCA-50-EXR |
16-80 |
TCA-80-EXR |
24-120 |
TCA-120-EXR |
32-160 |
TCA-160-EXR |
DUAL SCALE MODELS |
Current
Range (ARMS)
|
TCA-N/N-EXR
|
1-5 and 2-10 |
TCA-5/10-EXR |
1-5 and 4-20 |
TCA-5/20-EXR |
2-10 and 4-20 |
TCA-10/20-EXR |
2-10 and 8-40 |
TCA-10/40-EXR |
4-20 and 8-40 |
TCA-20/40-EXR |
8-40 and 16-80 |
TCA-40/80-EXR |
16-80 and 32-160 |
TCA-80/160-EXR |
NOTE: All models can be supplied with high voltage transformer by
appending -HV to model number for 20 kVRMS
transformer voltage rating or by appending -XHV to model number for
42.4 kVRMS
transformer voltage
rating. Examples: TCA-10/20-EXR-HV specifies a 10A and 20A dual scale
meter with 20 kVRMS
transformer and
TCA-160-EXR-XHV specifies a 160A single scale meter with 42.4 kVRMS
transformer.
|
|
RF Ammeter Accessories
TCA-N-EXM3 |
Remote Meter Set,
Single Scale, 3" meter |
TCA-N/N-EXM3 |
Remote Meter Set, Dual
Scale, 3" meter |
TCA-EXMP |
Standard Meter Panel
(Mounts up to four 3" remote
meters) |
TCA-EXMCP |
Enclosed
Meter Panel (Mounts up to four 3" remote meters and includes
TCA-PS2 power supply and provision for TCA-IBA
amplifier) |
TCA-IBA |
Integrating Buffer
Amplifier Assembly |
TCA-PS2 |
Power Supply (120/240
VAC, 50/60 Hz input, ±15 VDC/100
mA and 24 VDC/500 mA outputs) |
TCA-LS |
Conductor Bushing
(Increases standard TCT transformer
voltage
rating to 15 kVRMS) |
TCA-MB |
Mounting Bracket
(Mounts one or two standard TCT
transformers
or one meter unit) |
TCA-TS |
Transient Suppressor
Assembly (Type N T-Adapter with
connector mounted suppressor) |
TCA-RFR |
EMI/RFI Shielded
Enclosure (Houses TCA-EXR
rectifier/meter
unit and protects from dust, dirt, oil and water) |
SPECIFICATIONS
Frequency Range: |
0.5 to 2 MHz |
Current Ranges: |
1 to 160 Amperes, see table of available models |
Accuracy (Direct Reading): |
Better than 2% of full scale from 20 to 100% of
full
scale. Calibration
curve supplied for greater accuracy. Accuracy may be reduced if RF
currents induced by other stations are 5% or greater than the current
to be measured. |
Current Transformer: |
Shielded Toroidal Current Transformer (TCT series) |
Conductor Voltage to Ground
(RMS Equivalent of Peak Modulation Voltage):
|
TCT-N Series: |
10 kVRMS |
TCT-N-HV Series: |
20 kVRMS |
TCT-N-XHV
Series: |
42.4 kVRMS |
|
Electric Field Rejection: |
>100 dB |
Rectifier Circuit: |
Temperature compensated, linearized silicon
rectifier
circuit. |
Temperature Range: |
-40° C (-40° F) to +65° C (+150° F)
with rated accuracy |
Lightning Protection Switch: |
Toggle switch mounted on meter unit disconnects
and
grounds rectifier circuit. Dual range models have 3 way switch
with center off position. |
Interconnecting Cables: |
Standard six foot, 50 ohm coaxial cable supplied
to
connect transformer unit to rectifier/meter unit. Longer cable
lengths and double shielded coaxial cable are optionally available. |
Indicating Instrument: |
Taut band, mirror scale, ruggedized 1% linearity
meter
with 2.75 inch scale length |
Scale Expansion: |
Linear over useful range. |
Scale Divisions: |
Scale divisions above 1/5 full scale not greater
than
1/50 full scale (FCC specification) |
Modulation Characteristics: |
Indicates average RMS current (Minimum modulation
effect. Will show carrier shift.) |
For additional information on any of our products, please contact
Sales to
discuss your particular requirements:
Delta Electronics, Inc.
5730 General Washington Drive
P. O. Box 11268
Alexandria, VA 22312
|
Phone: (703) 354-3350
U.S. Toll Free: 1-800-8-DELTA-8 (1-800-833-5828)
Fax: (703) 354-0216
www.deltaelectronics.com
Email: sales@deltaelectronics.com |
The Delta Electronics logo is a registered
trademark of Delta Electronics, Inc.